6. Sunny Explorer

Preface

 

Configuration

Inverters.conf

inverter.1.mandatory.invertername=SomesunnyExplorerInverter
inverter.1.mandatory.wattpeak=2000
inverter.1.mandatory.kwhkwp=1000
inverter.1.mandatory.invertertype=6
inverter.1.mandatory.inputdirectory=C:/temp/js_input/sunny_explorer
inverter.1.mandatory.barcolor=0,0,120
inverter.1.mandatory.linecolor=0,0,120
inverter.1.mandatory.fromdate=01-01-2015
inverter.1.optional.comparelinecolor=0,0,170
inverter.1.optional.correctionfactor=1.00
inverter.1.optional.inclination=45
inverter.1.optional.orientation=263
inverter.1.optional.tilldate=
## Additional info: Locate the kWh column in a day file for the inverter and use it below Column A=1, B=2, C=3, D=4 and so forth.
## default value for the first inverter is 3
inverter.1.mandatory.kwhcolumnlocation=
## Added with version 2.0.6
## If you want to load the monthly files as well add this line.
## Open a monthfile and locate the daily yield for the first inverter the default value is 3
## When this line is missing the monthly files will not be loaded
inverter.1.optional.kwhmonthlocation=

Day files

These files can be recognized by their name. The full date is written in the filename. e.g. SunnySite20160101.csv

Month files

These files can also be recognized by their name. Ofcourse there are a lot less of these ( only one per month ). e.g. SunnySite-201601.csv